Rensair Compact 460i
€975.00 exc VAT
Rensair Compact destroys more than 99.97% of airborne bacteria and viruses.
Clean air has never been more important. We have made hospital-grade air purifiers available globally. The Rensair air purification technology was originally developed for Scandinavian hospitals, meeting strict air quality requirements. It is a patented solution that uses the most advanced purification technology and the efficacy is documented by independent laboratories.
The Rensair air purifier consists of a germicidal ozone free UVC lamp placed in the centre of a cylindrical high quality HEPA 13 filter, to not only capture but also inactivate viruses and bacteria trapped on the filter surface. The constant UVC illumination of the entire filtration area ensures a continuous disinfection process, resulting in a safer product to operate and maintain. The effectiveness of the Rensair air purifier is documented by independent laboratories including Eurofins, Norconsult and Oslo University Hospital.
The Rensair Q08A portable, hospital-grade air purifier
is a compact, flexible unit that is highly effective
in removing airborne particulate matter, including
pathogens (viruses and bacteria), pollen, dust and mould,
in small indoor spaces.
Leveraging Rensair’s proven HEPA, UVC and centrifugal
airflow technologies, the unit is capable of cleaning
up to 400m3 of air per hour on the maximum setting.
Specifications
Dimensions: H:65cm / 25.6in, Ø30cm / 11.8in
Dimensions in box: H: 72.5cm / 28.5in D: 37cm / 14.6in x W: 37cm / 14.6in
Net weight: 9.5kg / 21lbs
Gross Weight (including box): 11.3kg / 25lbs
Colour: White
HEPA filter: EU13 (EN 1822 class H13)
ELECTRICAL SPECIFICATIONS
CE Certified (UK & EU): 220-240V, ~50Hz, IEC C14 to C13 connector to allow for different power plugs
ETL Certified (US & Canada): 110-120V, ~60Hz, US type B power plug
Length of power cord: 3m / 9.8ft
UVC germicidal lamp: 18W, 254nm light
Sensors: PM2.5 sensor measuring μg/m3
Connectivity: WiFi connectivity and controls via the “Tuya Smart” App
PERFORMANCE
RENSAIR AIRFLOW VOLUME. Cubic Meters M3/HOUR. CUBIC FEET FT3/MINUTE. NOISE LEVEL (dBA). POWER USAGE (W)
Quiet setting 100 60 32 45
Low setting 210 125 45 110
Medium setting 240 140 49 120
High setting 280 170 54 130
Turbo setting 400 240 62 160
Tolerance +/- 10%
MAINTENANCE
The pre-filters need to be cleaned from time to time depending on dust accumulation on the sturdy mesh. Simply push down to release and lift out the pre-filters in order to vacuum clean them.
The HEPA 13 filter and UVC lamp need to be replaced every 5,000 operational hours (~12 months) in a simple safe and straightforward operation. The unit’s display notifies when this is required.
TECHNOLOGY TESTED BY INDEPENDENT LABORATORIES
Eurofins, NorConsult, the Danish Technological Institute and University Hospital Oslo.